TRATOS®Kynar/PVC Armoured
Cathodic Protection Cable

Kynar insulated, Polyvinylchloride (PVC) inner sheath, Galvanised steel wire armour, Polyvinylchloride (PVC) outer sheath, single core cable.

Energy Cables / Cathodic Protection Cables

This single-core armoured cable is designed for use as the connecting cable in cathodic protection systems worldwide, the armour lends itself to direct burial installations, although, for continuous immersion in water, an HDPE sheath gives greater protection. A fluoropolymer, Polyvinylidene fluoride (PVDF), Trade name Kynar, is a tough engineering thermoplastic, well known for its excellent resistance to a wide range of chemicals, most acids and acid mixtures, weak bases, halogens, halogenated solvents, hydrocarbons, alcohols, salts and oxidants. Kynar has high dielectric strength and excellent mechanical properties over a wide temperature range leading to it becoming a popular choice as a reduced wall primary insulation. Kynar has low permeability leading to its choice for special applications such as cathodic protection where chlorine and hydrogen gasses could be present.

Immediately over the inner layer of Kynar Tratos extrude an inner layer of High-Density Polyethylene (HDPE) Molecular Weight Polyethylene and then apply a helical layer of Galvanised Steel wires. The outer sheath is a thick layer of High-Density Polyethylene (HDPE) which is a member of the thermoplastic polyethylene (PE) family. The higher the density of the material, the greater the crystallinity and, therefore, the greater the hardness and stiffness. Primarily HDPE is used as a sheath because of its toughness and excellent water resistance, though it also has good resistance to chemicals and some solvents. However, it has only moderate resistance to oils and, although classed as halogen-free, has the disadvantage of being flammable. Low-temperature performance is very good. Unlike PVC sheathed cables which should not be installed or flexed when the temperature is below 0oC polyethylene sheathed cables can be safely installed at sub-zero temperatures.

Tratos XLPE/HDPE cables offer performance and reliability over an extended lifetime in cathodic protection applications where moisture or water are present continually or for long periods of time.  HDPE coverings also provide corrosion protection in installations where this is a problem.

Contact us:

Tel: +44 20 3148 5178

e-mail: sales@tratosgroup.com

Please don’t hesitate to contact us if you need additional information about our products.

Application

Tratos Cathodic Protection Cables are single conductor cables that are intended to carry a DC current to anodes and cathodes in a cathodic protection system. Tratos Cathodic Protection Cables are designed for use in both active and passive cathodic protection systems to eliminate and prevent corrosion in Metals. Tratos Armoured Cathodic Protection Cables are intended for installation in arduous operating conditions where the risk of mechanical damage is higher than normal. Tratos Cathodic Protection Cables are used to eliminate and prevention the corrosion of steel pipelines and steel storage tanks, offshore oil and gas installations, offshore wind farms, ships and other maritime applications installed in air or water.

Specifications

  • Conductors: Plain annealed copper conductors – BS EN 60228 Class 2
  • Insulation: Kynar- Polyvinylidene fluoride (PVDF)
  • Inner Sheath: High Density Polyethylene (HDPE)
  • Armour: Galvanised steel wire
  • Outer Sheath: High Density Polyethylene (HDPE)
  • Standard size range: 10mm2 to 50mm2 (up to 185mm2 available on request)
  • Standard insulation colours are RED and BLACK
Other colours are available on request.

Standards

Technical Specifications

  • Minimum ambient air temperature -55 oC
  • Maximum continuous conductor temperature +105 oC

Minimum bending radius – Fixed Installation – 8D

Maximum allowable pulling tension:

  • 50N/mm2 during installation
  • 15N/mm2 in service

Additional Information

CONDUCTOR – Material: Compacted tinned annealed Cu

Nominal CSA Nominal Diameter Max. resistance 20oC
mm2 mm Ω/km
10 3.8 1.84
16 4.65 1.16
25 5.83 0.734
35 6.8 0.529
50 8 0.391

Nominal CSA Nominal Diameter Max. resistance 20oC
mm2 mm Ω/km
10 3.8 1.84
25 5.83 0.734
35 6.8 0.529
50 8 0.391

INSULATION – Material: XLPE

Nominal thickness Nominal Diameter
mm mm
0.5 4.80
0.5 5.65
0.5 6.83
0.5 7.8
0.5 9.0

Nominal thickness Nominal Diameter
mm mm
0.5 4.80
0.5 5.65
0.5 6.83
0.5 7.8
0.5 9.0

INNER SHEATH  –  Material: HDPE

Nominal thickness Nominal Diameter
mm mm
0.8 8.0
0.8 8.85
0.8 10.4
0.8 11.4
0.8 12.8

Nominal thickness Nominal Diameter
mm mm
0.8 8.0
0.8 8.85
0.8 10.4
0.8 11.4
0.8 12.8

ARMOUR  –  Material: Galvanised steel wires

Nominal Diameter
mm
0.9
0.9
0.9
0.9
0.9

Nominal Diameter
mm
0.9
0.9
0.9
0.9
0.9

OUTER SHEATH  –  Material: HDPE

Nominal thickness Nominal Diameter Nominal weight
mm mm kg/km
1.5 11.2 140
1.5 12.05 200
1.5 13.23 290
1.5 14.2 395
1.5 15.4 505

Nominal thickness Nominal Diameter Nominal weight
mm mm kg/km
1.5 11.2 140
1.5 12.05 200
1.5 13.23 290
1.5 14.2 395
1.5 15.4 505