BS EN 60228
BS EN 60228 Standard specifies the nominal cross-sectional areas, in the range 0,5 mm2 to 2 500 mm2, for conductors in electric power cables and cords of a wide range of types.
Requirements for numbers and sizes of wires and resistance values are also included. These conductors include solid and stranded copper, aluminium and aluminium alloy conductors in cables for fixed installations and flexible copper conductors.
BS EN 60228 standard does not apply to conductors for telecommunication purposes.
The applicability of this standard to a particular type of cable is as specified in the standard for the type of cable.
Unless indicated to the contrary in a particular clause, BS EN 60228 standard relates to the conductors in the finished cable and not to the conductor as made or supplied for inclusion into a cable.
Informative annexes are included giving supplementary information covering temperature correction factors for resistance measurement (Annex B) and dimensional limits of circular conductors (Annex C).
Classification
The conductors have been divided into four classes, 1, 2, 5 and 6. Those in classes 1 and 2 are intended for use in cables for fixed installations. Classes 5 and 6 are intended for use in flexible cables and cords but may also be used for fixed installations.
- Class 1: solid conductors.
- Class 2: stranded conductors.
- Class 5: flexible conductors.
- Class 6: flexible conductors which are more flexible than class 5.
Products
TRATOS® Kynar-HMWPE Armoured
Cathodic Protection Cable
Tratos® Aerial Bundle Cable (ABC)
Tratos®SNE – SPLIT CONCENTRIC – LSOH SHEATH
Tratos® SNE – SPLIT CONCENTRIC Cable – PVC SHEATH
Tratos® WAVEFORM cable – 3 AND 4 CORE – LSOH SHEATH
TRATOS® C-TRI-RATED – Superflexible
TRATOS® Kynar-HMWPE
Cathodic Protection Cable
TRATOS®Kynar/PVC Armoured
Cathodic Protection Cable
TRATOS® XLPE/XLPE
Cathodic Protection Cable
TRATOS® XLPE/PVC
Cathodic Protection Cable
TRATOS® XLPE/HDPE
Cathodic Protection Cable
Contact us
Please, don’t hesitate to contact us for additional information on our company or our products.
Other News
-
While others talk about Superconductors, CERN in Geneva uses Tratos, ICAS, and ENEA Superconductors
-
Tratos UK Ltd Achieves Strong EcoVadis Sustainability Rating
-
Tratos will showcase new products at TOC Europe 2025 after collecting major projects
-
Exploring Innovation in Fibre Optics: Students Visit Tratos Facilities in Italy
-
Tratos Sustainability Report 2023: Engineering a Sustainable Future with Innovation at its Core
-
Tratos Celebrates a Successful Showcase at Middle East Energy 2025
-
Tratos participates in the UKEF Supplier Fair on Cabinda International Airport
-
Powering a Connected, Resilient Future of Global Britain