TRATOS® CW 1326/1179 PEUT UNDERGROUND – IN DUCTS

CW 1326 CABLE POLYETHELENE TWIN - SOLID INSULATION CABLE POLYETHYLENE TWIN - SCREENED - SOLID INSULATION.

Telecommunication Cables / Telecommunication Copper Cables / UK Telecom Cables

CW 1326/1179 PEUT UNDERGROUND IN DUCTS BT

Tratos is a long-established manufacturer of Telecommunication Cables, a family of cables used for the transmission of Data, Information, Voice and Images. Production at Tratos covers almost all the installation needs of Telecommunication Cabling.

These Outside Plant (OSP) Cables are used primarily drawn into underground ducts in the Secondary or Distribution (‘D’-side) of the local distribution Network.

These cables are manufactured as solid polyethylene-insulated jelly filled pair cable with plain copper conductors made up into units of 10 pairs or sub-units of 5 pairs. The required number of units or sub-units are stranded together before sheathing with a polyethylene sheath applied over a polyethylene coated aluminium foil moister barrier bonded to the sheath. This aluminium foil also acts as an electrostatic screen. The interstices of the cable are completely filled with a water-blocking compound, two rip cords are applied under the moisture barrier to ease removal of the foil and the sheath.

The standard number of pairs available is 2 Pr, 5 Pr, 10 Pr, 20 Pr, 30 Pr, 50 Pr and 100 Pr other numbers of pairs available on request.

An un-screened version of the cable is also available on request.

The cable meets or exceeds the requirements of CW 1326.

BT SPECIFICATION

  • CW 1326 Design guide
  • CW 1000
  • CW 1179
  • CW 1205
  • CW 1402
  • CW 2000

EN/ BS EN

  • BS EN 50290-23
  • BS EN 50290-24
  • BS EN 50290-28
  • BS EN 60228

IEC

  • IEC 60028
  • IEC 60189-1
  • IEC 60708

Contact us:

Tel: +44 20 3148 5178

e-mail: sales@tratosgroup.com

Please don’t hesitate to contact us if you need additional information about our products.

Application

Outside Plant (OSP) Cables are used primarily in the Secondary or Distribution (‘D’-side) Network They are used as primary cables in the local distribution networks drawn into underground ducts.

CONSTRUCTION

  • Conductor: Plain copper 0.5 mm
  • Insulation: Solid, PE
  • Cabling: Pair or quad; unit and sub-unit
  • Number of pairs: 2 Pr, 5 Pr, 10 Pr, 20 Pr, 30 Pr, 50 Pr and 100 Pr
  • Water blocking: Filling compound fully filling the interstices of the cable
  • Rip cords
  • Moisture barrier: Aluminium polyester tape
  • Sheath: PE

Standards

Technical Specifications

Operating temperatures between -20°C and +60°C

The Maximum Corrected Capacitance Unbalance between adjacent pairs: 275 pF/500m 

Maximum average conductor resistance: 91Ω per 1000m at 20°C

Minimum Insulation Resistance: 1,500 MΩ/km