Tratos®CNE – CONCENTRIC NEUTRAL EARTH – LSOH SHEATH
Tratos® CNE – CONCENTRIC NEUTRAL EARTH – LSOH SHEATH 0.6/1 KV – LSOH SHEATH LV polymeric insulated cables for use…
Please, don’t hesitate to contact us for additional information on our company or our products.
| Part and section | Title |
|---|---|
| Part 1 | General |
| Part 2 | Methods of test |
| Part 3 | Specification for distribution cables of rated voltage 0.6/1 kV |
| 3.1 | PVC insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
| 3.11 | XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
| 3.12 | XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
| 3.2 | PVC insulated split concentric cables with copper or aluminium conductors |
| 3.21 | XLPE insulated split concentric cables with copper or aluminium conductors |
| 3.22 | XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
| 3.4 | XLPE insulated copper wire waveform concentric cables with solid aluminium conductors |
| 3.5 | XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
| Part 4 | Specification for distribution cables with extruded insulation of rated voltages of 11 kV to 33 kV |
| 4.1 | Sinqle–core 11 kV to 33 kV cables |
| 4.11 | Single-core 33 kV lead sheathed cables |
| 4.2 | Three-core 11 kV cables |
| Part 5 | Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
| Part 8 | Specification for multicore and multipair cables for installation above and below ground |
| 8.1 | Single wire armoured and PVC sheathed multicore cable with copper conductors |
| 8.2 | Single wire armoured and PVC sheathed multipair cable with copper conductors |
| 8.3 | Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance |
| Part 1 | General |
| Part 2 | Methods of test |
| Part 3 | Specification for distribution cables of rated voltage 0.6/1 kV |
| 8.4 | Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance |
| 8.5 | Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath |
| 8.6 | Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors |