BS EN 50264
Railway rolling stock power and control cables having special fire performance
SCOPE: The BS EN 50264 series specifies cables for power, control and associated circuits, which, in the event of fire, will limit the risk to people and improve the safety of railways in general. It covers sheathed and unsheathed cables with insulation and sheath based on halogen-free materials for use in railway rolling stock.
BS EN 50264, which covers a range of cables rated at up to 3,6/6 kV with conductor sizes 1,0 mm² up to 400 mm², is divided into 5 parts under the generic title “Railway applications – Railway rolling stock power and control cables having special fire performance”.
Part 1: General requirements
Part 2-1: Cables with cross-linked insulation – Single core cables
BS EN 50264-2-1:2008 – Railway applications. Railway rolling stock power and control cables having special fire performance. Cables with crosslinked elastomeric insulation. Single core cables
Part 2-1 of BS BS EN 50264 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings:
- 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2);
- 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2);
- 1,8/3 kV unscreened, sheathed (1,5 mm2 to 400 mm2);
- 3,6/6 kV unscreened, sheathed (2,5 mm2 to 400 mm2).
All cables have class 5 tinned copper conductors to BS EN 60228, halogen-free insulation and halogen-free sheath, in the event of fire, they will limit the risk to people and improve the safety on railways in general.
They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 seconds.
The cables in this part of the standard BS EN 50264-2-1 are sometimes referred to as Standard Wall, having traditional insulation and sheath thickness.
Under fire conditions, the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 1, 2, 3 or 4 of BS EN 45545-1.
Part 2-2: Cables with cross-linked insulation – Multi-core cables
BS EN 50264-2-1:2008 – Railway applications – Railway rolling stock power and control cables having special fire performance – Part 2 – Cables with cross-linked elastomeric insulation – Part 2-2 – Multicore cables
Part 2-2 of BS EN 50264 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings:
- 300/500 V screened or unscreened (1 mm2, 1,5 mm2 and 2,5 mm2, number of cores from 2 to 40);
- 0,6/1 kV screened or unscreened, (1 mm2 to 50 mm2, 2, 3 and 4 core).
NOTE 1 Not all conductor sizes or number of cores are specified for every type.
All cables have class 5 tinned copper conductors to BS EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 seconds.
The cables in this part of the standard BS EN 50264-2-1 are sometimes referred to as Standard Wall, having traditional insulation and sheath thickness.
Under fire conditions, the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 1, 2, 3 or 4 of EN 45545-1.
Part 3-1: Cables with crosslinked insulation with reduced dimensions – Single core cables
BS EN 50264-3-1 – Railway applications – Railway rolling stock power and control cables having special fire performance – Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions – Single core cables
Part 3-1 of BS EN 50264 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings:
- 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2);
- 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2);
- 1,8/3 kV unscreened, sheathed (1,5 mm2 to 400 mm2);
- 3,6/6 kV unscreened, sheathed (2,5 mm2 to 400 mm2).
All cables have class 5 tinned copper conductors to BS EN 60228, halogen-free insulation and halogen-free sheath, in the event of fire, they will limit the risk to people and improve the safety on railways in general. They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90° C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 seconds.
The cables in this part of the standard BS EN 50264 are sometimes referred to as Medium Wall, having insulation and sheath thickness less than traditional values giving reduced dimensions.
Under fire conditions, the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 1, 2, 3 or 4 of BS EN 45545-1.
Part 3-2: Cables with crosslinked insulation with reduced dimensions – Multi-core cables
BS EN 50264-3-1 – Railway applications – Railway rolling stock power and control cables having special fire performance – Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions – Multicore core cables.
Part of BS EN 50264-3-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings:
- 300/500 V screened or unscreened (1 mm2, 1,5 mm2 and 2,5 mm2, number of cores from 2 to 40)
- 0,6/1 kV screened or unscreened, (1 mm2 to 50 mm2, 2, 3 and 4 core)
NOTE 1 Not all conductor sizes or number of cores are specified for every type.
All cables have class 5 tinned copper conductors to BS EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 seconds.
The cables in this part of the standard are sometimes referred to as Medium Wall, having insulation and sheath thickness less than traditional values giving reduced dimensions.
Under fire conditions the cables special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 1, 2, 3 or 4 of EN 45545-1.
Product Family: RAILWAYS & MASS TRANSIT CABLES/TRATOS ROLLING STOCK
Products
TRATOS RS UU MW
TRATOS RS UU-SW
TRATOS RS US MW SCREENED MULTI CORE
TRATOS RS US MW SHEATHED SINGLE CORE
TRATOS RS US SW SHEATHED SINGLE CORE
TRATOS RS US SW UNSCREENED MULTI CORE
Contact us
Please, don’t hesitate to contact us for additional information on our company or our products.
Related Case Studies
Related News
-
Hard-Line approach to Health & Safety at Tratos
-
Italian railways high speed trains use Tratos fire-resistant cables
-
Railway sector
-
New Generation of Enhanced Fire Performance cables for High-Speed Rail
-
Rail sector technical adviser expands Tratos cable know-how
-
Tratos hosts Rail Industry technical group seminar
-
MW TRATOS FIRESAFE SYSTEM